max EGT on start
760 c
max transient overload EGT
732 c
max continuous EGT
710 c
normal APU voltage
115 +/-3 (112-118)
normal APU frequency
400 Hz +/-10
allowable APU voltage
115 +/-8 (107-123)
allowable APU frequency
400 Hz +/-20 (380-420)
MINIMUM battery voltage with emergency power on
26 volts
battery amp range with emergency power on
10-35 amps
normal apu r.p.m. range
95-105%
starter duty cycle
1 min. on 4 min. off after 4 cycles, wait 30 min. before going through the cycle again
caution apu r.p.m. range
105-110%
what chapter in the natops is the apu checklist
9
apu fire
1 apu fire control switch - off & agent arm
2 agent- discharge
(if APU FIRE warning light remains on, discharge 2nd bottle)
3 turn on emergency power switch. vhf will turn on
maximun apu r.p.m.
110%
apu fire
loop a or b only
select the opposite loop that is illuminated and perform a loop integrity test on that loop system
apu LOW OIL PRESSURE
remember AIR-AUTO-OFF. turn the apu air off, place apu doors switch to auto (normally in auto), and turn the apu master switch off
apu HIGH OIL PRESSURE and at what temp
remember AIR-AUTO-OFF. turn the apu air off, place apu doors switch to auto (normally in auto), and turn the apu master switch off. above 120 c
aircraft batteries without a load
27 volts dc (vdc)
excessive battery charge
above 65 amps
when emergency power is on, voltage should not be below
26 volts
the apu egt idles between
200 c- 400 c
before shutting off apu what temp must you be below and for how long
400 c 2 min.
when does the egt at 760 c apply
only during start
when engaging the apu starter voltage should not be below
22 volts
tail compartment temp. high light
turn apu air switch off and close the pneumatic cross feeds. ensure there is no bleed air from the apu leaking into the tail compartment. if light doesn't go out secure apu. try lowering aft stairs and cat walk.
apu oil quantity
4 quarts (1 gallon). 1 quart from add line to fill line
what kind of starter is the apu
electric
what transfer bus powers the fire detection/protection
dc