Site Selection
|
SS Credit 1
|
|
|
SS Credit 1
|
Sustainable Sites
Site Selection 1-5 points |
|
|
SS Credit 2
|
Development Density and Community Connectivity
|
|
|
Development Density and Community Connectivity
|
Sustainable Sites credit 2
|
|
|
SS Credit 3.1
|
Public Transportation Access
|
1/2 mile of existing or funded communter rail, light rail, or subway station 1/4 mile dfrom 2 bus lines |
|
SS Credit 3.2
|
Bicycle storage and changingrooms
|
Provide secure bicycle racks and or storage within 200 yards of a main building entrance for 50% or> of tenants · Provide shower and changing facilities in the building or within 200 years of building entrance for .5% of FTE’s (full time equivalent occupants) |
|
SS Credit 3.2
|
Parking Availability
|
# of parking spaces must not exceed minimum required by zoning law · preferred parking for carpools and vanpools capable of serving 5% of building occupants or no parking whatsoever |
|
Brownfield Development
|
SS Option 2
Path 1: |
ASTME E1903-97 |
|
Stormwater Design- Quantity Control
|
SS Option 2
Path 2 |
Reduce imperviousness of the site |
|
Stormwater Design- Quality Control
|
SS Option 2
Path 3: |
US EPA 840B9 2002 National Technical Information Service (NTIS) PB93 EPA Office of Water (OWA) |
|
Heat Island Effect- Non Roof
|
SS Option 2
Path 4 |
shaded hardscape (trees, landscape) + shaded hardscape (solar panels) + shaded hardscape (architectural elements) + total harscape with SRI = or > 29 + open grid paving that is 50% pervious must = 30 % of total hardscape |
|
Heat Island Effect- Roof
|
SS Option 2
Path 5 |
ASTM E1980-01 ASTM E408-71 ASTM E903-96 |
|
SS Credit 1- Option Path 6:
|
Light Pollution Reduction 1 pt.
|
Option 1: automatic control of non emergency lighting fixtures programmed such that power is reduced 50%-100% during non business hours. Option 2: shielding with transmittance of less than 10% on all exterior openings with automatic control programmed to close between 11pm and 5 am |
|
Light Pollution Reduction =
|
SS Credit 1- Option Path 6:
|
Option 1: automatic control of non emergency lighting fixtures programmed such that power is reduced 50%-100% during non business hours. Option 2: shielding with transmittance of less than 10% on all exterior openings with automatic control programmed to close between 11pm and 5 am |
|
SS Credit 1- Option 2 Path 7
|
Water Efficient Landscaping- Reduce by 50%
1pt |
Use a design case to compare to a baseline case using the pages of equations provided by USGBC |
|
Water Efficient Landscaping- Reduce by 50%
1pt |
SS Credit 1- Option 2 Path 7
|
Use a design case to compare to a baseline case using the pages of equations provided by USGBC |
|
SS Credit 1- Option 2
Path 8 |
Water Efficient Landscaping- No Potable Water Use or no irrigation
2 pts. + Path 7 |
|
|
Water Efficient Landscaping- No Potable Water Use or no irrigation
2 pts. + Path 7 |
SS Credit 1- Option 2 Path 8
|
|
|
Innovative Waste Water Technologies
|
SS Credit 1- Option 2 Path 9
2 pts. |
· Reduce potable water used for sewage conveyance by 50% OR ·Treat 100% of on site waste water to 3rd party standards |
|
SS Credit 1- Option 2 Path 9
2 pts. |
Innovative Waste Water Technologies
|
· Reduce potable water used for sewage conveyance by 50% OR · Treat 100% of on site waste water to 3rd party standards |
|
Water use Reduction- 30% Reduction
1pt |
SS Credit 1- Option 2 Path 10
|
|
|
SS Credit 1- Option 2 Path 10
|
Water use Reduction- 30% Reduction
1pt |
|
|
SS Credit 1- Option 2 Path 11
|
On Site Renewable Energy
2 pts |
ASHRAE 90.1 Demonstrate renewable energy technology system’s contribution to total energy requirements of the building |
|
On Site Renewable Energy
2 pts |
SS Credit 1- Option 2 Path 11
|
ASHRAE 90.1 Demonstrate renewable energy technology system’s contribution to total energy requirements of the building |
|
SS Credit 1- Option 2 Path 12
|
Other Quantifiable Environmental Performance 1 pt.
|
Any green feature implemented according to the requirement of another LEED rating system (different from those in LEED ID + C) credit or exemplary performance of any of the above credits. |
|
Other Quantifiable Environmental Performance 1 pt.
|
SS Credit 1- Option 2 Path 12
|
Any green feature implemented according to the requirement of another LEED rating system (different from those in LEED ID + C) credit or exemplary performance of any of the above credits. |