ITE (info tech equipment) is typically sized for ----- of their UPS full load capacity.
80%
If you are installing a direct hydrogen fed fuel cell system indoors, the max standard cubic feet is limited to -----
3500 SCF
Which method is usually used to control harmonics?
Over sized neutral conductors
Fuel cells designed for commercial primary backup generators are -----
25 to 250 kW
High temperature fuel cells deliver up to ----- electrical efficiency
45%
The output load can be few by % UPS ----
parallel set of UPS modules
Power systems that supply ITE centers are designed so that power is -----
not interrupted
The term Emergency Power Off (EPO) refers to a switch in the ITR -----
service disconnect (D)
Which following fuel cell systems operate avove 1800 F?
Solid Oxide type
Which Company is the world leader in design, manufacturing .... of large scale fuel systems since 2001 and has delivered more fuel cell MW that any other in the world?
Fuel Cell Energy (FCE)
Fuel cells operate by chemically bonding -----
Hydrogen and Oxygen
A Standby UPS in normal mode, acts as a ----- for utility power.
filter (it filters irregularities in input)
----- can be a serious consequence of failure of an ITE.
All the above
A UPS is used as a source of what type of power for critical loads?
Constant power
The greatest % of fuel cell companies are manufacturing for the following -----
Light Commercial/ Residential/ Backup
What is the size of the largest fuel cell system currently installed in North America?
It is 2 mW installed by FCE
What type of UPS Conversion is used on a personal computer?
Standby
If you are installing a direct hydrogen fed fuel cell system outdoors that standard cubic feet is -----
less than 3500 SCF
Cell phones are usually banned from ITE centers because -----
they can interfere with data transfer
Large UPS sites aer usually rated at -----
150 kVA and above
Fuel cells use an ----- to convert energy
electrical chemical process
Tier 1 ITE centers are the most -----
common
If one UPS module fails, -----
the other UPS module takes over
In what section of a typical UPS system are you likely to find a storage battery or set of batteries mounted?
fuel cell stack
A disadvantage of ------ design is that both UPS design, module, rating must be of the same manufacturer.
parallel redundant system