How many oxygen or helium/oxygen gas bottles can be charged at once?
6
What is the minimum scf required to drive the Haskel pump?
10 scf
What is the drive air regulated to?
125 psi (+/- 5)
What are the three major subassemblies of the OTPA?
- Pump Assembly
- Manifold Assembly
- Interconnecting Hoses
What is the drive air relief valve set at?
Lifts at 140 psi
Resets at 130 psi (+/- 5)
What does the pilot valve do?
- Will shut the pump down when the supply pressure drops below 350 psi
- Will shut the pump down when the supply pressure reaches 3250 psi
What is the O2 pressure relief valve set at?
Lifts at 3300 psi
Resets at 3000 psi (+/- 50)