External air leakage from the APU heat shield is allowable?
(True or False) |
True
|
|
In the event of an APU fire, how many possible locations are available to shutdown the APU?
|
3
|
|
When number 3 Tank FWD boost pump switch light is not turned on within 2 minutes, APU will appear on the WAP.
(True or False) |
True
|
|
An APU fire is indicated by which of the following?
|
MASTER WARNING lights on INSTRUMENT panel, APU is displayed on CUE, LOOP A and LOOP B lights on ENVIR panel, Central Aural Warning System (CAWS) and APU warning horns, FIRE light on APU panel.
|
|
Activation of the APU Off/ARM switchlight on the APU panel will provide an automatic shutdown of the APU.
(True or False) |
True
|
|
When the APU access doors are open, the aircraft mounted fire extinguisher system is not sufficient to extinguish the fire.
(True or False) |
True
|
|
How can the APU be started if the external electrical power is not available?
|
Battery power may be used when external power is not available
|
|
Set start control switch on APU panel to start and release and identify which parameters are increasing?
|
Exhaust Gas Temperature (EGT) and Revolutions Per Minute (RPM's)
|
|
What area must the operator ensure is clear prior to an APU start?
|
Ensure APU inlet and exhaust areas are clear.
|
|
An automatic shutdown occurs when APU EGT exceeds _______ above 95% RPM.
|
621º degrees celcius
|
|
When External Power and the APU generator PWR switch is in use the AC TIED light shall go off.
(True or False) |
True
|
|
What action should be taken when the APU fails to speed up during battery start?
|
Reset the APU start circuit breakers
|
|
Maximum EGT during APU startup is 485º degrees celcius.
(True or False) |
False
|
|
The APU Start Control Switch is spring loaded to the run position.
(True or False) |
True
|
|
To prevent injury to personnel or damage to equipment, do not operate the APU under the following?
|
With the fire detection system loop A and loop B inoperative
|
|
The APU fuel consumption per hour is _______
|
500 lbs per hour
|
|
After setting the APU Start Control switch to start position, what EGT indication are you looking for?
|
EGT increases and stabilizes
|
|
An automatic shutdown occurs when the APU RPM exceeds_________?
|
104%
|
|
What are the indications of a successful APU loop A and loop B test on the enviornmental panel?
|
Loop A and Loop B lights come on, CAWS sounds, Master warning press to reset lights on glareshield comes on, Fire light on APU comes on, WAP displays APU
(ALL OF THE ABOVE) |
|
The APU PWR switch on the electrical panel shall remain on until the APU is completely shutdown.
(True or False) |
True
|
|
What does a HIGH light and an automatic shutdown of the APU during normal operations indicate?
|
Overspeed Condition
|
|
Press and hold which switch light to test all lights and digital indicators?
|
ANN/DIGT test switchlight
|
|
Allow APU to operate with no load for a minumum of _____ prior to shutdown.
|
2 minutes
|
|
What is the position of the APU off/arm switchlight during normal APU operation on overhead PNL?
|
OFF/raised
|
|
What is the APU starter motor duty cycle?
|
Do not exceed 3 starts or attempts in one hour with a minimum of one minute between starts of attempts.
|
|
Where are the 3 APU emergency shutdown locations?
|
Cockpit, loadmaster, SPR
|
|
What are the cockpit APU emergency shutdown procedures?
|
Press OFF/ARM, lift and press AGENT/DISCH, press 3 Tank FWD, set START CONTR switch to OFF, open APU CTRL PWR/PSDAU 1 (C15), set EXT PWR switch to OFF, set BATT switch of OFF, shutdown generator set
|
|
What are the APU emergency shutdown procedures for the loadmaster and SPR locations?
|
Place FIRE CONTROL on APU FIRE pnl to OFF/SILIENCE then to AGENT ARM
Raise guard, set AGENT DISCH to DISCH |