- Front
- Back
Disinfection is a less lethal sterilizationprocess that kills disease causing micro-organisms and has _ types which are?
|
2: Chemical/Heat
|
|
The Environmental Protection Agency (EPA)classifies disinfectants as high, intermediate, & low-level based on theeffectiveness and contact time bacterial spores, mycobacterium tuberculosis,lipid and non-lipid viruses, and?
|
Vegetative Bacteria
|
|
Glutaraldehyde’s of 2-3.2% are FDA registeredand are classified as what level disinfectants?
|
High-level
|
|
Chlorine dioxide is a high-level disinfectantthat must be discarded daily and works in __ minutes?
|
3-6min. |
|
Biocidal activities of iodophors is accomplishedwithin 10-15 minutes and is classified as a ___ level disinfectant?
|
Intermediate-level |
|
What disinfectants are classified asintermediate-level and are useful on metal, glass, rubber, and plastic?
|
Phenolics
|
|
What level should ultrasonic cleaner reservoirsbe filled with ultrasonic solution?
|
1/2-3/4
|
|
How long is the time-related shelf life ofnonwoven blue wraps, parchment paper, and Dennison wraps?
|
30days |
|
How long is the time-related shelf life of heatseal or peel packs?
|
365 days
|
|
What is the most dependable and economicalmethod of sterilization?
|
Steam under pressure (Autoclave)
|
|
For successful dry heat sterilization thetemperature must reach ____ for ___minutes? |
320F-375F/90min |
|
Chemical vapor sterilization must reach atemperature of ___ for ___ minutes at ___psi?
|
270F/20-40min/20psi |
|
Ethylene oxide (ETO) gas sterilization can beachieved at ___ for ___hours?
|
120F/4-12hrs
|
|
Who must be notified of positive sterilizationtests? |
Infection Control Officer (ICO) |
|
What test is used to check the vacuum seal onpre-vacuum sterilizers?
|
Bowie-Dick test
|
|
|
|
|
|
|
|
|
|