- Front
- Back
1-1/4" pipe can drain______ fixture units vertically |
1 fixture unit |
|
1-1/4" pipe can drain_______ fixture units horizontally |
1 fixture unit |
|
1-1/4" pipe can vent_______ fixture units |
1 fixture unit |
|
The drain for 1-1/4" pipe can be_________ |
45' long |
|
The vent for 1-1/4" pipe can be__________ |
45' long |
|
an 1-1/4 trap must be _______ minimum from its vent |
2-1/2" |
|
with a maximum trap arm length of ______ |
30" or 2' 6" |
|
1-1/2" pipe can drain _______ fixture units vertically |
2 fixture units |
|
1-1/2" pipe can drain ______ fixture unit horizontally |
1 fixture unit |
|
1-1/2" pipe can vent________ fixture units |
8 |
|
The drain for 1-1/2" pipe can be_________ |
65' |
|
The vent for 1-1/2" pipe can be _________ |
60' |
|
an 1-1/2" trap must be_____ minimum from its vent |
3" |
|
1-1/2" pipe must have a maximum trap arm length of _______ |
42" or 3' 6" |
|
2" pipe can drain______ fixture units vertically |
16 fixture units |
|
2" pipe can drain_______ fixture units horizontally |
8 fixture units |
|
2" pipe can vent _________ fixture units |
24 fixture units |
|
The drain for 2" pipe can be________ feet long |
85 |
|
The vent for 2" pipe can be_______ feet long |
120 |
|
an 2" trap must be _______ from its vent |
4" |
|
2" pipe will have a maximum trap arm length of ________ inches or feet |
60" or 5' |
|
2-1/2" pipe can drain ______ fixture units vertically |
32 fixture units |
|
2-1/2" pipe can drain ______ fixture units horizontally |
14 fixture units |
|
2-1/2" pipe can vent _________ fixture units |
48 fixture units |
|
an 2-1/2" drain can be ________ feet long |
148 feet |
|
an 2-1/2" vent can be ________ feet long |
180 feet |
|
3" pipe can drain ______ fixture units vertically |
48 fixture units |
|
3" pipe can drain ______ fixture units horizontally |
35 fixture units |
|
3" pipe can vent ______ fixture units |
84 fixture units |
|
an 3" drain can be ______ feet long |
212 feet |
|
an 3" drain can be ________ feet long |
212 feet |
|
a 3" trap must be ______ from its vent |
6" |
|
a 3" pipe can have a maximum trap arm length of__________ |
72" or 6' |
|
4" pipe can drain _________ fixture units vertically |
256 fixture units |
|
4" pipe can drain ________ total fixture units horizontally unless _______ pitch then you must multiply fixture units by_______? |
216 fixture units unless 1/8" pitch is used then multiply fixture units by .8 |
|
4" pipe can vent ________ total fixture units |
256 fixture units |
|
an 4" drain can be _______ feet long |
300 feet |
|
an 4'" vent can be________ feet long |
300 feet |
|
a 4" trap must be____ minimum from its vent |
8 inches |
|
4" pipe can have a maximum trap arm length of ________ |
10' or 120" |