- Front
- Back
How many oxygen or helium/oxygen gas bottles can be charged at once? |
6 |
|
What is the minimum scf required to drive the Haskel pump? |
10 scf |
|
What is the drive air regulated to? |
125 psi (+/- 5) |
|
What are the three major subassemblies of the OTPA? |
- Pump Assembly - Manifold Assembly - Interconnecting Hoses |
|
What is the drive air relief valve set at? |
Lifts at 140 psi Resets at 130 psi (+/- 5) |
|
What does the pilot valve do? |
- Will shut the pump down when the supply pressure drops below 350 psi - Will shut the pump down when the supply pressure reaches 3250 psi |
|
What is the O2 pressure relief valve set at? |
Lifts at 3300 psi Resets at 3000 psi (+/- 50) |