Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
118 Cards in this Set
- Front
- Back
What are the 13 Transverse Bulkheads (Watertight) aboard a WMSL?
|
Frames 9, 10, 16, 22, 28, 36, 44, 52, 64, 70, 76, 82, 88
|
|
How many transverse bulkheads are there aboard a WMSL?
|
13
|
|
How many fire zones are there on a WMSL?
|
4 Fire Zones
|
|
What are the Fire Zone Bulkheads?
|
Frames 28, 52, 76
|
|
Compartment Numbering:
A |
Storage Areas
|
|
Compartment Numbering:
AA |
Cargo Holds
|
|
Compartment Numbering:
C |
Command & Control
|
|
Compartment Numbering:
E |
Machinery Space
|
|
Compartment Numbering:
WW |
Cargo Water Tanks
|
|
Compartment Numbering:
FF |
Cargo Fuel Tanks
|
|
Compartment Numbering:
L |
Living Spaces
|
|
Compartment Numbering:
M |
Magazines
|
|
Compartment Numbering:
T |
Vertical Access
|
|
Compartment Numbering:
Q |
All Other Spaces
|
|
Compartment Numbering:
W |
Water Tanks
|
|
Compartment Numbering:
F |
Fuel Tanks
|
|
Compartment Numbering:
J |
JP-5
|
|
What does CCOL stand for?
|
Compartment Check-Off List
|
|
Types of Fittings and Valves:
ATC |
Air Test Cap
|
|
Types of Fittings and Valves:
DDV |
Deck Drain Valve
|
|
Types of Fittings and Valves:
COV |
Cut Out Valve
|
|
Types of Fittings and Valves:
FP |
Fire Plug
|
|
Types of Fittings and Valves:
QAWTD |
Quick Acting Watertight Door
|
|
Types of Fittings and Valves:
WTD |
Watertight Door
|
|
Types of Fittings and Valves:
WTH |
Watertight Hatch
|
|
Types of Fittings and Valves:
WTS |
Watertight Scuttle
|
|
Valve Colors:
Red |
Fire Main
|
|
Valve Colors:
Striped Red and Green |
AFFF
|
|
Valve Colors:
Dark Blue |
Potable Water
|
|
Valve Colors:
Striped Light Green and Blue |
Chill Water
|
|
Valve Colors:
Striped Red and Light Blue |
AFFF Concentrate
|
|
Valve Colors:
Yellow |
Fuel
|
|
Valve Colors:
Yellow and Black Striped |
Lube Oil
|
|
Valve Colors:
Dark Purple |
Refrigerants
|
|
Valve Colors:
Dark Gray |
High Pressure Air
|
|
Valve Colors:
Tan |
Low Pressure Air
|
|
Valve Colors:
Dark Green |
Sal Water
|
|
Valve Colors:
Gold |
Sewage
|
|
Valve Colors:
White |
Steam
|
|
Valve Colors:
Light Blue |
Feed Water
|
|
Valve Colors:
Purple |
JP-5
|
|
Valve Colors:
Orange |
Hydraulic Fluid
|
|
DC Sound Pwered Phone Circuit
|
X1JC
|
|
What is the Gun Control Sound Powered Phone Circuit?
|
JP
|
|
What is the Casualty Circuit?
|
Pumpkin Line and X40J
|
|
How many minutes does and EEBD last?
|
10 Minutes
|
|
Where can 1MC Announcements be made from?
|
Bridge, Quarterdeck, Forward Vestibule, Aft Vestibule, DCC
|
|
What are the different Ship's Alarms?
|
General, Collision, Chemical, Emergency Response, Helo Crash On Deck
|
|
How many square cubic feet does an SCBA hold?
|
66sq cubic feet at 4500psi
|
|
How long does an SCBA last?
|
About 45 Minutes
|
|
Where are kite phones located?
|
CIC, CO's Cabin, DCC, Bridge, Helo Control
|
|
When does the audible alarm on the SCBA cyllinder go off?
|
At 25% time left on SCBA,
|
|
What does the SCBA pass device do?
|
It emits audio alert when no movement from the individual is sensed
|
|
How does water extinguish a fire?
|
Removes Heat
|
|
How does CO2 extinguish a fire?
|
Displaces Oxygen (O2)
|
|
What is the water to AFFF ratio?
|
97% water, 3% AFFF
|
|
How does AFFF distinguish fire?
|
Forms Vapor Barrier and Cools
|
|
How does PKP distinguish fire?
|
Interrupts Chemical Chain Reaction
|
|
What does APC stand for?
|
Aqueous Potassium Bicarbonate
|
|
How does APC extinguish a fire?
|
Creates a Vapor Barrier
|
|
What does PKP stand for?
|
Purple Potassium Powder
|
|
What type of Fire Main is aboard a WMSL?
|
Single Main Dry Riser
|
|
How many sections can the Fire Main be divided by on a WMSL?
|
2
|
|
What makes up the fire Tetrahedron?
|
Fuel, Heat, Oxygen, and Uninhibited Chemical Chain Reaction
|
|
What does white, gray smoke indicate?
|
Alpha Fire
|
|
What does blue smoke indicate?
|
Charlie Fire
|
|
What does black smoke indicate?
|
Bravo Fire
|
|
What is Conduction?
|
Transfer of heat through an object like metal
|
|
What is Convection?
|
Transfer of heat through a motion of gases or liquids
|
|
What is Radiation?
|
Transfer of heat across a gap
|
|
What is the best extinguishing agent for an alpha fire?
|
Water or AFFF
|
|
What is the best extinguishing agent for a bravo fire?
|
AFFF, PKP, CO2
|
|
What is the best extinguishing agent for a charlie fire?
|
Secure power, CO2, Water Fog from 4' (short bursts)
|
|
What is the best extinguishing agent for a delta fire?
|
Jettison
|
|
How many fire pumps are on a WMSL?
|
5
|
|
How many gallons is a fire pump rated for?
|
1000 per minute at 125psi
|
|
What is the standard size fire hose?
|
1.5 inches
|
|
How many firefighting hose stations are there on a WMSL?
|
98 Stations
|
|
How many gallons does the AFFF storage tank hold?
|
225 Gallons
|
|
What spaces have installed AFFF?
|
JP-5 Pump Room
Incinerator Room Hangar AMR Bilge FMMR Bilge AMMR Bilge Generator Room |
|
How long does a 5 Gallon container of AFFF last for under continuous use?
|
120 Seconds
|
|
What spaces does the HFP System protect?
|
Paint Locker
HAZMAT Flam Locker |
|
What is the danger of using the HFP System?
|
It produces toxic gas when exposed to fire
|
|
What is the range and duration for an 18lb PKP extinguisher?
|
19 Feet, 14 Seconds
|
|
What is the range and duration for an 27lb PKP extinguisher?
|
21 Feet, 20 Seconds
|
|
What is the range, duration and weight of the CO2 extinguishers onboard a WMSL?
|
4-6 Feet, 40-45 Seconds, 15 lbs
|
|
What is the weight, range and duration of an AFFF extinguisher onboard a WMSL?
|
11 lbs, 10-12 Feet, 55 Seconds
|
|
What are the four positions on a Vari-Nozzle?
|
Wide Angle, Narrow Angle, Straight Stream, Flush
|
|
How many Cubic Feet Per Minute is a Box Fan rated for?
|
3200 cubic ft/minute
|
|
What powers the Box Fan?
|
115 AC
|
|
How many cubic feet per minute is the RAMFAN 2000 rated for?
|
2000 cubic feet per minute
|
|
What powers the RAMFAN 2000?
|
The Fire Main via an 1.5" Hose
|
|
What size supply hose does the Peri-Jet Eductor have?
|
2.5 Inches
|
|
What size is the discharge hose for a Peri-Jet Eductor?
|
4 Inches
|
|
What size is the supply hose for an S-Type Eductor?
|
1.5 Inches
|
|
What size is the discharge hose for an S-Type Eductor?
|
2.5 Inches
|
|
What is the largest size of debris that a Peri-Jet Eductor can pass?
|
2.5 Inches in Diameter
|
|
What powers the Electrical Submersible Pump (ESP)?
|
440V
|
|
With a 50 Foot Static Head, how many gallons per minute is the ESP rated for?
|
180 Gallons Per Minute
|
|
With a 70 Foot Static Head, how many gallons per minute is the ESP rated for?
|
140 Gallons Per Minute
|
|
What does PECU stand for?
|
Portable Exothermic Cutting Unit
|
|
When running ESP's in tandem, which Pump do you turn on first?
|
The lower one
|
|
How many gallons per minute is the P-100 rated for with 39 feet of lift?
|
68 gallons per minute @ 45 psi
|
|
How many gallons per minute is the P-100 rated for with 20 feet of lift?
|
100 Gallons Per Minute @ 83 psi
|
|
How many horsepower is the P-100 rated for?
|
10 Horsepower
|
|
What is the fuel tank capacity and how many hours will it run for the P-100?
|
1.45 Gallons, 2.75 Hours
|
|
What size is the suction hose and discharge hose on a P-100?
|
Suction- 3", Discharge- 2.5"
|
|
What is the maximum PSI for a soft patch?
|
150 PSI
|
|
What is the maximum PSI for a Jubilee Patch?
|
Excess of 100 PSI
|
|
What is the maximum PSI for a Synthoglass patch?
|
150 PSI
|
|
What two systems can you not use synthoglass patches on?
|
Fuel (only in emergency) and Potable Water (never)
|
|
How long does it take for a fiberglass patch to harden around a rupture?
|
30 minutes
|
|
What are the three shoring configurations?
|
I-Type
K- Type H- Type |
|
What is the strongest shoring configuration?
|
I-Type
|
|
What is the weakest shoring configuration?
|
H-Type
|
|
What are the two lengths of metal shoring?
|
3-5 Feet and 6-11 Feet
|
|
When fully extended, a 3-5 feet metal shoring maximum load is?
When collapsed? |
12,000 lbs
20,000 lbs |
|
When fully extended, a 6-11 feet metal shoring maximum load is?
When collapsed? |
6,000 lbs
20,000 lbs |