33 Cards in this Set
- Front
- Back
List the methods of heat transfer |
Conduction, convection, radiation |
|
Describe heat energy |
Energy in motion from hot to cold |
|
Purpose of a high limit switch on a basic gas fired furnace |
Shuts of MGV when the plenum over heats |
|
What are 4 purposes of automatic controls |
Comfort, economy, convenience, safety |
|
What is the range of a high limit switch |
89-93 (basic furnace) 82-94 (combination fan control) |
|
Typical range setting for a fan OFF switch |
32-38 |
|
What is the rating for a high efficiency furnace |
90-98% AFUE (Annual fuel utilization efficiency) |
|
In a combination gas valve what does the thermocouple supply |
Power unit |
|
Taking a open circuit voltage on a thermocouple should be between? |
26-32mV |
|
The main exhaust fan is interlocked with what |
Furnace fan
Keep the interior and exterior pressure the same |
|
What is typically the difference between a 24 V and 120 V thermostat |
24 V has an anticipator |
|
Is the rollout switch in a high-efficiency furnace a automatic reset or a manual reset |
Manual reset |
|
What two auxiliary components associated with mid and high-efficiency furnaces |
Humidifier and electric air cleaner |
|
List for types of humidifiers that can be used on furnaces |
Rotating drum Rotating disk Flow-through humidifier Standing water absorbent pad |
|
the combustion air blower forces air directly into the |
The flue |
|
Heating systems are rated by input values typically using the units |
Btu/h kWatt |
|
RTD stands for |
Resistance temperature detection |
|
In a basic heating system what devices initiate a change |
Thermostats and fan control |
|
Liquid bulb type sensor has few benefits to its design what are they |
Good for liquid temp measurements Ambient temperatures doesn't affect Capillary tubes much |
|
Thermeopiles can create up to how many millivolts during operations |
800 mV |
|
Solenoid gas valves open do too what kind of force |
Magnetic |
|
Diaphragm valves open when what's applied |
Gas pressure |
|
Which type of temperature sensing device can with stand 1500° |
Pyrometers |
|
Combination gas valves have four main components |
Gas valve Manuel on/off pilot Main gas valve Safety gas valve |
|
Taking a close circuit reading of a thermocouple should be? |
7.5-15 mV |
|
Last four factors that affect human comfort |
Humidity ,air movement ,radiation and temperature |
|
A counter-flow furnace |
Forces got air out the bottom Requires more than one high limit Commonly used in mobile homes |
|
What is connected in series with the thermocouple |
Powerpile or thermopile |
|
Thermeocouples generates a voltage by a principal called what |
Thermoelectricity |
|
What does the fan ON setting come on between |
49-60 |
|
What temperature does the fan shut off at |
32-38 |
|
What temperature does the blower fan shut off at |
32-38 |
|
Humidity n temp in doors |
40% 22 degrees |