how many volts is the starting system on the c-17?
|
24 vdc.
|
|
what is the refrigerant capacity of the c-17?
|
125 lbs.
|
|
how many btu/hr does the c-17 provide?
|
300,000 btu/hr.
|
|
what is the airflow pressure of the c-17?
|
150 lb/min at 2 psig.
75 lb/min at 4 psig. |
|
engine idle speed?
|
550-600 rpm.
|
|
normal operating rpm's?
|
1750 rpm.
|
|
clutch cut-in rpm's?
|
700 rpm or lower.
|
|
operating time per full tank of fuel?
|
8 hours of full cooling capacity at 1750 rpm's.
|
|
at what pressures do the high and low cutout switches disengage?
|
high: 365 psi
low: 20 psi |
|
low compressor oil cutout switch cuts out and cuts un at what pressures?
|
cut out: 15 psi
cut in: 20 psi "manual reset has 120 sec time delay". |
|
what is the receiver's releif valve set at?
|
450 psi.
|
|
what is the melting point of the receiver's fusible metal plug?
|
212 degrees F
|
|
the c-17 is designed for operation in temperatures in what range?
|
0-110 degrees F.
|
|
what is the delivery air temp of the c-17?
|
40-50 degrees F.
|
|
what is the maximum rpm's the speed control governor will allow?
|
2300 rpm's.
|
|
what is the purpose of the precooler coil?
|
to lower or dehumidify the conditioned air temperature to a dew point of 40 degrees F.
|
|
which compressor is equiped with an oil cooler?
|
carrier.
|
|
what is the definition of dew point?
|
the temperature at which condensation takes place.
|
|
at what rpm will overspeed switch S9 close?
|
2300 RPM.
|
|
what is the designation for the engine shutdown solenoid?
|
L6
|
|
what relay engages the clutch once the unit the selector switch is placed in air conditioning/pump down mode?
|
K3 (master relay)
|
|
when the selector switch is placed in air conditioning mode, what relay opens the solenoid valves?
|
K2.
|
|
how many solenoid valves are energized when the unit is placed in air conditioning mode?
|
4. (L1, L2, L3, L4).
|
|
which solenoid supplies the precooler coil with refrigerant when the unit is placed in air conditioing mode?
|
L3.
|
|
WHICH SOLENOID SUPPLIES THE HOT GAS BYPASS VALVE WITH REFRIGERANT WHE THE UNIT IS PLACED IN AIR CONDITIONING MODE?
|
L4.
|
|
which 2 solenoid valves supply refrigerant to the aftercooler coils?
|
L1 and L2.
|
|
which 2 solenoid valves are closed when the unit is placed in dehumid mode?
|
L1 and L2.
|
|
a float switch (S5) in the reserve tank closes when the fuel remaining drops to ____.
|
one hour.
|
|
moving the selector switch to pump down deactivates which relay?
|
K2 (pump down relay) which deenergizes all 4 solenoids.
|