Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
13 Cards in this Set
- Front
- Back
Where are the ship drawing index (SDI) maintained?
|
In the ships log room or technical library. It lists all the drawings applicable to that ship.
|
|
Who is the sole provider of U.S. Navy ship fitted ICCP systems?
|
Electrocatalytic, Inc.
|
|
What NSTM chapter covers Cathodic protection?
|
NSTM Chapter 633
|
|
What records and reports, maintained in the ships log room, often provide important information on ICCP system components?
|
U/W repair/working reports
ship maintenance/repair records u/w hull inspection reports u/w hull cleaning reports diver hull inspection data sheet (NAVSEA Form 4730/7) |
|
A ship check is required to establish liason with whom?
|
Ships Engineering Officer and the work center with responsibility for the ICCP system
|
|
If the anode of a reference cell gland assembly is located in an enclosed compartment, what requirement must be considered?
|
Obtaining gas-free access IAW NSTM 074 Vol 3 section 20
|
|
What are the 2 anode replacement procedures?
|
Dry procedure
Wet procedure |
|
How is the dry procedure conducted and what kind of epoxy does it use?
|
It's conducted in a dry habitat that permits the use of epoxy capastic
|
|
Of the two procedures to repalce anodes, which procedure is more costly in both time and expense?
|
The dry procedure
|
|
Approximately how much time does constructing and fitting of a habitat add to the repairs of a anode replacement?
|
48 hours
|
|
Underwater epoxy is unlikely to be applied successfully if the ambient temperture is below ____ degrees.
|
50 degrees
|
|
How long does it take to replace a anode,
Wet procedure? Dry procedure? |
Wet: 2-3 days
Dry: 4-5 days |
|
How long does it take to replace,
Reference Cells? Dielectric shields? |
1-2 reference cells in 2 days, dependent on the extent of damage.
|