30 Cards in this Set
- Front
- Back
WHAT DO THE NAVY USES TO MEASURE RADIANT AND CONVECTION HEAT TRANSFER TO OR FROM THE BODY? |
WBGT METER OR AUTOMATED HEAT STRESS SYSTEM (AHSS).
|
|
THE WBGT INDEX IS CALCULATED USING ____,____, AND ___.
|
DRYBULB, WET-BULB, AND GLOBE TEMPERATURE
|
|
WHAT IS PHEL?
|
PHYSIOLOGICAL HEAT EXPOSURE LIMITS. HOW LONG AN INDIVIDUAL MAY BE EXPOSED SAFELY TO HEAT STRESS CONDITION. IT IS DETERMINED BY THE WBGT INDEX AND PHYSICAL EXERTION LEVEL.
|
|
FOR SHIPS WITHOUT AN AUTOMATED HEAT STRESS SYSTEM (AHSS) INSTALLED, HOW MANY PORTABLE, CALIBRATED AND OPERABLE WBGT METERS SHOULD BE ONBOARD?
|
AT LEAST TWO
|
|
WHO IS RESPONSIBLE FOR REVIEW, AND INITIAL DAILY HEAT STRESS SURVEYS THAT RESULT IN REDUCED STAY TIMES?
|
CO
|
|
WHO REVIEW ALL ENGINEERING AND NON-ENGINEERING HEAT STRESS SURVEYS TO DETERMINE OBVIOUS INACCURACIES, REDUCED PHEL STAY TIME?
|
MDR
|
|
WHO ENSURE DRY BULB THERMOMETERS ARE INSTALLED AND TEMP ARE MONITOR AND RECORDED?
|
EACH DEPARTMENT; REACTOR, SUPPLY, ENGINEERING...
|
|
PLACEMENT OF THE ______ THERMOTERS MAY BE IN OR OUT OF VENTILATION AIR STREAM, BUT MUST BE HUNG AT LEAST _____FT FROM ANY SUPPLY VENTILATION TERMINAL/OPENING.
|
DRY BULB; 2 FEETS
|
|
WHAT IS USED TO OBTAIN ACCURATE AND RELIABLE DATA ON HEAT STRESS CONDITION ONBOARD SHIPS?
|
HEAT STRESS SURVEY RECORDED BY DRY, WET AND GLOBE TEMPERATURE
|
|
TRUE OR FALSE
DRY BULB THERMOMETERS DO NOT REQUIRE CALIBRATION. |
TRUE
|
|
AUTOMATED HEAT STRESS SYSTEM LOCATED NEAR VENTILATION, THE SENSOR SHOULD BE LOCATED IN RELATION TO THE VENTILATION DUCT IN SUCH THAT AIRFLOW TO THE SENSOR DOES NOT EXCEED _____ FPM.
|
600
|
|
WHAT MUST BE AVALIABLE ON BOARD SHIPS, IF AHSS WORKSTATION IS UNAVAILABLE DUE TO POWER FAILURE SECURING OF THE WORKSPACE, ETC.
|
DRY BULB THERMOMETER
|
|
IF DB TEMPERATURE EXCEED 100,90,85 THE SPACE SUPERVISOR SHALL____, THE DB READING AND ____. THE WATCH SUPERVISOR SHALL DIRECT HEAT STRESS SURVEY TO BE CONDUCTED AND ENFORCE THE RESULTING STAY TIME.
|
CIRCLE IN RED; NOTIFIED WATCH SUPERVISOR
|
|
WHAT IS USED TO DETERMINE ENVIRONMENTAL HEAT STRESS CONDITION?
|
WBGT METER
|
|
THE HEAT STRESS SURVEYOR SHALL CONDUCT THE FIRST WBGT MEASUREMENT IN THE WORKSPACE _____ MINUTES TO ENABLE IT TO EQUILIBRATE TO THE SUROUNDING AREA AND ____ FOR THE NEXT LOCATION.
|
5 MINUTES; 3 MINUTES
|
|
THE SURVEYOR SHALL RECORD THE HANGING DRY BULB TEM ON HEAT STRESS SURVEY SHEET. IF THE DIFFERENCES BETWEEN THE HANGING DB THERMOMETER AND THE DB TEM MEASURED WITH THE WBGT METER IS ________, THE DB IS NOT REPRESENTATIVE OF THE TEM AT THE WORKSPACE.
|
5 DEGREE OR GREATER
|
|
____ SHALL PROVIDE A FISCAL YEAR-END SUMMARY OF SHIPBOARD HEAT STRESS CASES FROM THE WESS DATABASE BY TYPES OF OPS, AND SHIP CLASS TO CNO.
|
NAVENVIROHLTCEN
|
|
HOW MANY PHEL CURVES ARE THERE?
|
SIX
|
|
PHEL CURVE I
|
NORMAL OPS
|
|
PHEL II
|
DIFFICULT OR MORE ACTIVE THAN NORMAL OPS
|
|
PHEL CURVE VI
|
HEAVY WORK
|
|
____ IS THE FLEET'S NUMBER ONE OCCUPATIONAL HEALTH HAZARD.
|
NOISE- INDUCED HEARING LOSS
|
|
WHO CONDUCTS NOISE MEASUREMENT SURVEY?
|
INDUSTRIAL HYGIENIST, OCCUPATIONAL AUDIOLOGIST OR BY OTHER PERSONNEL TRAINED BY AN INDUSTRAIL HYGIENIST OR OCC AUDIOLOGIST |
|
WHO RETAIN A COPY OF THE NOISE MEASUREMENT DATA?
|
SAFETY OFFICER
|
|
DESIGNATED HAZARDOUS NOISE AREA AND EQUIPMENT THAT PRODUCE HAZARDOUS SOUND LEVELS SHALL BE LABEL WITH __________
|
NAVMED 6260/2-WARNING
NAVMED 6260/2A-LABEL |
|
WHAT IS FORM DD2215?
|
REFERENCE (BASELINE) HEARING TEST
|
|
INDIVIDUALS ASSIGN TO THE HCP WILL RECEIVE A HEARING TEST AND TRAINING ______
|
ANNUALLY
|
|
RESULTS OF HEARING TEST SHOULD BE PERMANENTLY RECORDED INTO______
|
DEFENSE OCCUPATIONAL HEALTH READINESS SYSTEM-HC (DOHRS-HC) AND HEALTH RECORD
|
|
HOW OFTEN DO MDR UPDATE THE "TICKLER FILE"?
|
MONTHLY
|
|
ACTIVITIES THAT DO NOT USE DOHRS-HC, SHOULD CONTACT THE ______FOR GUIDANCE IN INCLUDING TEST DATA IN THE HEARING CONVERSATION DATA
|