NG Max Continuous |
99% |
|
NG Intermediate |
102% |
|
NG Transient (12 seconds) |
105% |
|
NG Ground Idle |
63% |
|
NP No Limit |
110% |
|
NP Transient (12 seconds) |
127% |
|
TGT Max Continuous |
1490° |
|
TGT Intermediate (30 Minutes) |
1564°F |
|
TGT Maximum (10 minutes) |
1612°F |
|
TGT Contingency (2.5 Minutes) |
1657°F |
|
TGT Transient (12 Seconds) |
1740°F |
|
TGT Start Limit |
1564°F |
|
TGT No Operation Allowed above |
1740°F |
|
Torque Max Continuous |
500 ft/lbs |
|
Torque Intermediate (30 Minutes) |
543 ft/lbs |
|
Torque Transient (12 Seconds) |
700 ft/lbs |
|
Free Air Temp (FAT) |
-65°F - 135°F |
|
Fuel and Oil Leakage Limit |
2 cc’s or 10 drops per minute |
|
HMU Vent Drain Leak Running |
50 cc’s per hour |
|
HMU Vent Drain Leak Static |
50 cc’s per hour |
|
Oil Cooler Leakage Limit |
No Leakage Allowed |
|
ODV Drain at Shutdown |
100cc Max - 15cc/min |
|
All drains on false start |
200cc max |
|
Ignition Exciter Duty Cycle |
2 on 3 off 2 on 3 off 2 on 48 off |
|
Time between starts |
30 Seconds |
|
Time to idle |
30 seconds |
|
Time to light off |
10 seconds or 30 seconds on first start |
|
Oil Pressure B Sump Flux |
+/- 5 psi |
|
Oil Consumption |
133 cc/hr (1 qt per 6.5 hours) |
|
Oil Temp |
95°-275°F |
|
Max Oil Temp |
300°F |
|
Vibrations on Start |
2.8 IPS |
|
Vibrations on Start |
2.8 IPS |
|
Transient Vibes Less Than 5 Seconds |
2.8 IPS |
|
Vibrations on Start |
2.8 IPS |
|
Transient Vibes Less Than 5 Seconds |
2.8 IPS |
|
Steady State Vibrations |
1.5 IPS |
|
Air Dyno Vibration Limits |
2 mils peak to peak max |
|
Air Dyno Vibration Limits |
2 mils peak to peak max |
|
All Power Settings Vibe Limit |
2.0 IPS |