39 Cards in this Set

  • Front
  • Back
Vent pipes protect fixture traps against _____________.
siphonage
Under certain circumstances, traps serving sinks that are part of the equipment of bars, soda fountains, and counters ______________.
need not be vented
One factor for determining the size of a vent pipe is __________.
its length
The total area in square inches that will provide sufficient aggregate cross-sectional vent area for required 4-inch house sewer is ________________or greater.
12.56 sq in
The maximum horizontal length permitted for a required 2-inch vent pipe is _____________ feet.
40
The diameter of an individual vent shall not be less than ____________ inches.
1 -1/4
A 2-inch vent pipe will serve a total of ___________ fixture units.
24
Each vent pipe or stack shall extend through its flashing and shall terminate vertically above the roof at least _______________ inches.
6
The distance from any vent pipe opening above the roof shall be at least ____________inches from any vertical surface.
12
Horizontal termination of vents from any openable window, door opening, air intake, or vent shaft shall be not less than _____________ feet.
10
Except for alleys and streets, vent termination from property lines shall not be less than ___________________.
3 feet
Vents terminating in roof areas used for sunbathing shall be extended above the roof at least ______________ feet.
7
Joints at the roof around vent pipes shall be made watertight by the use of ______________.
flashings
Parallel vent stacks are required for drainage stacks that extend above the building drain _____________.
10 stories or more
The parallel vent stack shall be connected to the drainage stack by means of a _________ vent.
yoke
The pipe size for the common vent serving lavatories installed back-to-back shall be not less than ______________ inches.
1 -1/2
Horizontal vent pipes shall be level or so graded as to drip back by gravity to the ____________.
drainage pipe they serve
The minimum size vent pipe that may serve a 4-inch trap is __________ inches.
2
Increasing vents one pipe size will ____________.
allow vents of longer lengths
Changes in direction of vent piping shall be made by ____________ .
appropriate use of fittings
A drainage stack extends 14 stories above the building drain and is served by a parallel vent stack. A relief yoke vent connection between the vent stack and the drainage stack is required at floors _____________ and ______________.
4, 9
The fitting that is required for making the yoke vent intersection with the drainage stack is a ___________.
wye branch
What is the minimum size for a yoke vent intersection with the drainage stack?
not less in diameter than either the drainage or the vent stack, whichever is smaller
If, due to structural conditions, horizontal vents are less than 6 inches above the overflow rim of the fixture, the horizontal portion shall be installed with __________________________________.
drainage material and fittings and grade to drain
Vent terminals in locations having minimum design temperatures below 0°F shall be a minimum of ______________.
2 inches
Copper tube shall not be used for _______________.
chemical waste
ABS or PVC DWV piping installations exposed within ducts or plenums shall be limited to a flame spread index of not more than 25 or a smoke index of 50 except for _______________.
singe-family homes
Sheet lead used for flashings of vent terminals shall be not less than ___________ pounds per square foot.
3
Long mains shall be provided with relief vents at intervals of _______________ feet.
100
Water closets, bathtubs, showers, and floor drains within one or two bathrooms located on the same floor level for private use shall be permitted to be vented by a _____________ vent.
wet
Horizontal wet venting is ______________.
allowed for 2 bathrooms in a dwelling or guest room on the same floor
The fixture that serves as a dry vent connection to the horizontal wet vent is a ________________.
lavatory
The vent system shall be designed to prevent a trap seal from being exposed to a pressure differential on the outlet side of the trap that exceeds ____________ inch(es) of water column.
1
The horizontal wet vent shall not be less than 2 inches in diameter for _____________ dfu or less.
4
The dry vent connection to the wet vent shall be a(n) ________________ vent.
individual
The __________fixture drain or trap arm connection to the horizontalwet vent shall be downstream of any fixture drain or trap arm connections.
water closet
An engineered vent system shall be designed by _____________ and approved in accordance with Section 301.4.
a registered design professional
Joints at the roof, around pipes, shall be made water tight by the use of ______________.
flashing material
For 5 or more drainage fixture units, ____________ inch diameter pipe is the smallest size allowed.
3