Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
57 Cards in this Set
- Front
- Back
What features of the BISMP will no longer be found in the AISMP security pit control station |
Secondary door raise, lower, off switch and an access shaft light switch |
|
Opening the primary door is only possible if the |
Vault door is removed and the lock bolt is retracted |
|
What BISMP seconder door top operation would not be normally performed by technician on a AISMP secondary door top |
Manually retracting the lock bolts |
|
What must be verified before the secondary door can be secured |
Both combination locks are operational |
|
Upon entering the security pin retraction window of time, the SARC commanded operations that must occur to lower the secondary door include retracting the |
Actuator locking bar and locking bolts |
|
What MSB maintained equipment item is required to penetrate in a AISMP launch facility but not BISMP |
Site activation remote control |
|
Entering the electro mechanical actuator system into enhanced maintenance mode is achieved by setting the mode switch on the |
SDCA to maintenance and the EMA gear Box safety pin is engaged |
|
Which secondary door control assembly panel houses timer circuits that provide control of the site penetration delay timer and security pin retraction timer |
Back |
|
At a BISMP launch facility, it is important to switch the secondary control switch in the secondary pit control station to off before entering the launcher equipment room because the |
EMLA selector switch would be ineffective |
|
Which major electro mechanical actuator system component is partially charged by the lowering of the secondary door and supplements launch facility commercial power to raise the secondary door |
Energy storage system |
|
Which major electro mechanical actuator system component may use commercial or auxiliary power to run the EMA |
Motor drive cabinet |
|
The hydraulic ram assist with opening the launcher closure door |
Forcing the lock pin down |
|
The purpose for making reference points along the launcher closure rail is to |
Permit recovery strap installation to the cable pin underneath the LC door to stop it at certain points |
|
During launch facility forced entry, and electro mechanical team begins repair actions on the fault combination lock assembly after the |
SCS is installed and the launcher equipment room penetration procedures have been completed |
|
What would be reported at the launch control center if there was an attempt to unlock the security pit vault door |
Inner zone alarm |
|
What wing 1 launch facility security system feature does not exist at wing 3 or wing 5 launch facility |
Outer zone switch loop |
|
How many alternating current generators does the MAF motor generator have |
2 |
|
White wing 3 and when 5 launch control center has no more than 10 storage batteries connected in series parallel |
Primary LCC |
|
The battery charger for the missile alert facility storage batteries is contained in the |
Power supply group |
|
How are the storage batteries configured at all wing one launch control centers |
8 pairs of batteries connected in series parallel |
|
What power output does the diesel-electric unit produce at a wing 3 and when 5 launch facility in the event of a commercial power failure |
120/208 VAC, 3 phase, 60 hertz only |
|
What component installed on the MAF motor generator is not installed on the launch facility motor generator |
60 Hz AC generator |
|
When the distribution Box connects ordinance devices in order to test loads, this means the |
Safety control switch key is installed |
|
The launch control centers interconnecting Box provides an interface between the |
Electrical surge arresters and electronic equipment |
|
What components of an electrical surge arestor module limit the current entering the system during a surge condition |
20 ohm resistors |
|
What feature prevents the cables from being damaged when the shock mounted floor moves |
Shock loops |
|
What launch facility interconnecting Box component device will only be used in the LF it's designed for due to its site specific signal distribution |
Sorting plug |
|
What device in a launch facility interconnecting Box protects against undesirable signals which may have been picked up on the hardened intersite cabling system cables |
Pulse suppressor assembly |
|
Which electrical filter assembly located outside the electrical surge arrester vault protects the security lines |
F-1343/GSW-13 (urd 10443) |
|
Electro magnetic interface filtering for the AISMP secondary door is through |
14 electrical surge arrester modules |
|
Which weapon system control console component will provide an indicator for a fire alarm |
Auxiliary alarm panel |
|
What processes the commands and provides reports of missile and ground equipment status during ground operations |
Digital computer unit |
|
What launch facility component contains digital data line scanning, seize and lock out circuits |
Message processor drawer |
|
What launch facility drawer would you connect a controller monitor to in order to accomplish tape load procedures |
Guidance and control coupler |
|
What launch facility drawer contains electro magnetic pulse sensing circuitry |
Ultra high frequency receiver |
|
Under what conditions will a launch control center register another launch control center as being down |
Failing to transmit proper operational status integrations for 240 seconds |
|
What provides the mechanism for encrypting and decrypting messages in the command and control system |
Secure data unit |
|
What is performed if a launch facility does not register a valid encrypted operational status integration for 240 seconds |
Airborne launch control center command entry |
|
About how many gallons of coolant does the tank of the guidance section liquid cooler store |
7 |
|
In addition to a ground maintenance reply 25, what else will be reported to the launch control center when the missile guiding set reaches 80 ゚F |
Nothing else |
|
Aside from hydraulic lines, what is the last component in the guidance section liquid cooler the coolant flows through before entering the missile guidance set |
Control valve |
|
A decrease in the thermostat or resistance would indicate a |
Temperature increase in the missile guidance set |
|
Doing power applied check out, what action, if any, is required if the red no go indicator on the electronic control amplifier illuminates |
Shut down the missile guidance set manually |
|
What minute man system monitors missile functional performance, provides signals and ground power, maintains the liquid coolant, and the environmental control required to sustain missile operation until launch |
Operational ground equipment |
|
Which of the following is the controller monitor not required for aero space vehicle equipment start up |
Reentry system maintenance is accomplished |
|
During the digital computer unit memory loading, where is the program data contained before it is loaded into the DCU memory |
Magnetic tape cartridge |
|
Why are operational gound equipment and aerospace vehicle equipment start up normally not required during code change loading |
Guidance and control system is already in strategic alert |
|
Digital computer unit program loading requires the use of a cartridge tape unit, controller monitor, |
Cable set, and LFLC |
|
If an error indicator on condition and output status of the cartridge tape unit is parity error stop, which of the following will be unsuccessful |
Conditioning cycle |
|
The tape ID block tells the operator that the tape cartridge is for a particular |
Launch facility |
|
How does the cartridge tape unit determine when the end of file is reached |
A tape mark is detected |
|
The computer memory security check number consists of how many digits |
Eight |
|
When does the digital computer unit exit into strategical alert |
Completion of the alignment mode |
|
What indicates the battery has already been turned on and the static random access memory contains stored data during digital computer unit initialization sequence |
A battery flag discrete set false |
|
What are the 2 alignment modes available durring ground initialization in the minuteman system |
Initial and restart |
|
What is the launch readiness mode of the guidance control set |
Strategic alert |
|
Who is required to remove or install the operational keying variable |
Authorized code handling team |