Where is the APU located |
Section 48 |
|
What are the limits for electrical and pneumatic supply from APU |
Electrical 42000ft Pneumatic 19000ft |
|
What are the functions of the APU control unit |
Fuel control Load compressor IGV control Surge control Protective shut down Load prioritisation Bite |
|
What are the bite routines of APU control unit |
Pre start bite Monitor bite Self test bite |
|
When is the monitor bite carried out |
Continuously when APU running |
|
Name the analog shutdown systems |
Over speed 107% EGT overtemp 661c |
|
Name some digital shut down conditions |
Fire Over speed 109% EGT overtemp High oil temp Low oil ox Slow start Ignition failure Reverse airflow Loss of dc power |
|
What are the indications for protective shutdown |
EICAS APU FAULT message and fault light |
|
How is shutdown accomplished |
Over speed shutdown circuit |
|
What are the 3 major modules of APU |
Power section Load compressor Accessory gearbox |
|
What is driven off the accessory gearbox |
Oil pumps Fuel pump and FCU Cooling fan Starter motor Ac generator |
|
How can you access the plenum chamber |
Panel in APU compartment forward bulkhead |
|
Other than exhaust gas what else is ducted out through the exhaust |
Unwanted bleed air |
|
What is included in the APU vent and drain system to allow monitoring of components |
Inspection caps |
|
What is included in start control |
Timed acceleration Speed sequencing Ultimate temp trim |
|
What are the significant speed switch points |
7% fuel and ignition on 50% starter dropout 95% load available and ignition off |
|
How is EGT temp measured |
Four individual chrome alumel thermocouples |
|
What is included in the oil pump |
Px pump Px regulator valve Px relief valve Filter Scavenge pump |
|
What is the purpose of the de oiling valve |
Introduce air into the oil pump when oil temp is below 25f to limit viscous drag during start |
|
When is the oil cooler bypassed |
When oil temp is below 176f |
|
What will happen if Px differential across the generator scavenge system filter exceed 35 psi when oil temp is above 115f |
Protective shutdown |
|
Why is the gearbox pressurised |
Ensure there are no oil leaks in the bleed air system |
|
What is the hyd source for the load compressor inlet guide vanes |
Fuel at 250psi |
|
What components make up the fuel system |
Flow divider FCU fuel nozzles |
|
What does the flow divider do |
Distribute fuel to primary and secondary nozzles |
|
What happens if APU shutdown is initiated with bleed air in use |
90 sec cool down period |
|
What is the resting position of the IGVs |
Closed |
|
What are the modes of the IGV |
Idle Duct Px ECS Main engine start Inflight |
|
When are the IGV full closed and full open |
Full closed at idle Full open at main engine start & in flight |
|
What is the normal position of the surge control valve |
Open |
|
What will high EGT CAUSE THE IGVs to do |
Modulate closed |