A continuous vent is defined as

A vent pipe that is an extension of a vertical section of a branch or fixture drain

A branch vent is best defined as

A junction of two or more vent pipes

What is the maximum cumulative change of direction that cleanouts are required on the fixture drain serving a kitchen sink?

90°

The maximum spacing of cleanouts for two-way rodding over 4" is:

170' ( 52m )

Why are vent pipes increased by at least one pipe size but not less than 3" before going through the roof?

Protect from frost

Why are vent pipes increased by at least one pipe size but not less than 3" before going through the roof?

Protect from frost

The minimum size dual vent serving fixtures with an 1 ½" trap and a 1 ¼" trap would be:

1 ¼"

A dual vent means:

A vent pipe that serves 2 fixtures and connects at the junction of the trap arms

According to table 2.5.8.1., what is the minimum permitted size for a wet vent?

1-1/2"

According to table 2.5.8.1., what is the minimum permitted size for a wet vent?

1-1/2"

What is the largest size trap arm or fixture drain that can drain into a wet vent?

3" emergency floor drain

What would be the maximum number of tank type WC's that could drain into a 3" wet vent?

None

A trap is required for subsoil drainage pipe if:

it drains into a combined sewer

What is the proper order of fittings on a sump discharge (with direction of flow)?

union, check valve, full port valve

A trap is required for subsoil drainage pipe if:

it drains into a combined sewer

⭐️ TQ

Where a subsoil drainage pipe is connected to a sanitary drainage system, the connection shall be made:

on the upstream side of a trap with a cleanout

Where a subsoil drainage pipe is connected to a sanitary drainage system, the connection shall be made:

on the upstream side of a trap with a cleanout

⭐️TQ

The thermostat in a domestic water heater is normally set at what temperature?

140°F ( 60° )

The dip tube has a small hole near the top of the tank. This is to:

prevent the siphoning of the hot water tank

A discharge tube from a hot water heater should:

end within 12" ( 300mm ) of the floor

The temperature pressure relief valve on a hot water tank is designed to open at:

210°F ( 99°C )

The main purpose of the dip tube in a hot water tank is to:

prevent the cold water from mixing with the hot water

When testing a water system with air, what pressure must be maintained and for how long?

700kPa ( 100psi )


for 120 minutes

A shut off valve is required on the supply pipe to every:

water closet

A pressure regulating valve on a water distribution system should provide a down stream pressure of no more than:

80 psi

According to the code, what is the minimum water supply size for a bathtub?

1/2"

What is the water line fixture unit rating for a domestic clothes washer?

1.4FU

What is the minimum supply pressure for a tank operated water closet?

Manufacturers specifications

What is the minimum supply pressure for a tank operated water closet?

Manufacturers specifications

What is the maximum temperature setting on a shower valve?

120°F ( 49°C )

A service sink is installed with a preferable:

3" P trap standard

Why does a clothes washer require a loop in the drain?

to prevent the machine from draining by gravity

What is the maximum horizontal offset in a wet vent Larger than 2"

2.5m

What is the minimum height of a laundry standpipe as well as being above flood level rim?

24" ( 600mm )

A commercial dishwasher has a:

2" trap worth 3 FU

What is the maximum horizontal offset in a wet vent 2"and less?

1.2m

The two basic types of commercial and residential garbage disposal units are

continuous feed and batch feed

What is the maximum horizontal offset in a wet vent 2"and less?

1.2m

The two basic types of commercial and residential garbage disposal units are

continuous feed and batch feed

A garbage grinder must:

Be drained through a Trap

What is the maximum horizontal offset in a wet vent 2"and less?

1.2m

The two basic types of commercial and residential garbage disposal units are

continuous feed and batch feed

A garbage grinder must:

Be drained through a Trap

Vent pipes shall be installed without depressions.

True

What is the water fixture unit load for a 6 LPF or less with a flush tank?

2.2

What is the table for sizing the minimum water supply to a fixture for distribution system?

2.6.3.2.A

What is the minimum water supply pipe size for a bidet?

3/8"

What is the water velocity of the hot distribution piping in a residence?

1.5

What is the water fixture unit load of a domestic dishwasher?

1.4


This toilet design is known as

Siphon Jet Bowl


This toilet design is known as

Siphon Jet Bowl

What table do we use to determine fixture unit load for drainage?

2.4.9.3

How do we determine the size of waterline to serve a fixture?

NPC Table 2.6.3.2A

What is the minimum length of a flood drain trap arm?

18”

Water closets with 6 litres per flush are considered to be

ULF

Statement:


Provision shall be made for maintaining the trap seal of a floor drain

True

A 4” building sewer shall have a grade of at least:

1-100

What is the minimum size of building sewer connected to a public sewer?

4”

A waste stack is sized according to:

The number of fixture units and the number of FU's from any one storey

When is it necessary to install a backwater valve on a fixture?

when they are below grade

Backwater valves should always be:

Accesible

Backwater valves should always be:

Accesible

What is the minimum size building drain according to the N.P.C. 2020?

3"

What is the minimum size cleanout serving a 4” branch?

3"

What is the maximum length of an 1 1/4" trap arm?

1.5m


6’

What is the minimum required size of a roof terminal serving an 1 ½" vent, where the vent pipe passes through a roof and may be subject to frost closure?

3"

Nominally horizontal ABS or PVC plastic pipe must be supported at least every:

4' ( 1.2m )

A double sanitary T fitting shall not be used to connect the trap arms of:

back outlet WC's

The minimum size of an individual vent serving a fixture with a 4" trap is:

1-1/2"

What is the maximum accumulative change of direction for a water closet trap arm?

225°

Trap arm, as is defined in the National Plumbing Code, means:

the portion of fixture drain between the trap weir and the vent pipe fitting

Vents are installed to prevent trap seal loss caused by:

back pressure

The minimum size wet vent serving a water closet and a basin is:

2"

A soil-or-waste pipe may serve as a wet vent provided that there is not more than one nominally horizontal offset in the wet vent, and the offset does not exceed__________for pipes 2 inches or less in size.

1.2m