What is the maximum distance from the bottom of the soil or waste stack the clean out fitting is required under certain conditions?

Not more than 10 feet (3m) upstream of the bottom of the stack

The minimum size clean out serving an 8 inch building sewer is

A manhole

A stack vent would be defined as

Event that is the extension of a soil or Waste stack

According to the tables, what is the minimum size of a waist stack?

1 1/4”

What is the minimum size of an individual vent serving a fixture with a 4 inch trap?

1 1/2”

Which of the following types of traps seal loss would be solved by installing a vent?

Back pressure

To size an individual vent you need to know the

Trap size

Branch vent is best defined as

A vent pipe connecting two or more individual vents

What is the largest size branch or fixture drain that can discharge into a stack vent

This is not allowed

What is the maximum number of elbows that could be used on a water closet trap arm

1- 90 degree Elbow and 6- 22.5 Degree Elbows

A branch drain is serving one bathtub and one laboratory what is the minimum size

1 1/2”

A Sanitary tee cannot be used

At the base of a stack and to connect horizontal drains

A drainage system starts at the:

Flood level rim

The minimum grade on a 4 inch building drain is

1%

A fixture drain Connects?

The trap to another part of the drainage system

A floor drain does not need to be separately vented when the trap arm is

3” incise and at least 18” (450 mm) long

Where would you most likely find a slip joint

On a FOP

What is the minimum some vent size?

2”

The fixture unit rating for a macerating water closet is

4”

What is the minimum size of a secondary stack thats serving water water closet

1 1/2”

How much clearance should be provided to access a clean out

The clean out shall be in an accessible location

The maximum distance between wye clean outs on a 4” building drain is

50’ (15m)

An “invertwould be

The bottom inside surface of a horizontal pipe

The type of support normally used for vertical CISP is a

Riser clamp

How many hangers would be required for 22 m (72’) of 1/2” copper tube?

10 ( 22m divide 2.5m (table 2.3.4.5) = 8.8, round up to 9 and always add 1 = 10)

0.8 mm thick and 18 mm wide perforated strapping is acceptable to be used to support pipe sizes up to and including

4”

Vertical steel pipe must be supported at

Every second floor

What is the minimum height of water that must be applied when testing a building drain

10’ (3m)

What is the minimum height of water that must be applied when testing a building drain

10’ (3m)

An air test on a drainage system requires the test be held for at least

15 minutes

What is the minimum size of a building sewer and a rural application

3”

The max from developed length of a 2 branch vent with 20 fixture units is?

46 m ( Table 2.5.8.3)

The purpose of a vent stack

Is to relieve pressure at the base of the soil stack

Why is an offset RV sized one size smaller than an SV instead of a VS?

Because you will not have a VS on a three-story building ( VS are only required on buildings 5 stories or more)

The type of water closet that is manufactured in one piece is a

Siphon Vortex

The standpipe for an automatic clothes washer is usually installed to

Prevent the machine from draining by gravity

The FLR on the kitchen sink is usually how far from floor

36” (900mm)

The total fall on a trap arm must not exceed

One inside pipe diameter

The maximum change of direction which may be made in a laboratory trap arm is?

135°

A close couple toilet uses gravity to flush the toilet how does a Siphon vortex low profile one piece toilet work

It uses tank water above and below the rim of the bowl

The minimum distance between a trap and its vent ( except for a floor drain) is

Two pipe diameters

The outlet from a floor mounted water closet may drop a total of

1.0m (39”) before running horizontally

The purpose of a vent is to

Allow free flow of air and gases through the system.


Reduce the chance of traps your loss.


Reduce back pressure.

The maximum length of a trap arms serving a 3” floor drain at a minimum grade is

3.75m (12’)

Develop length means

The length along the centreline of the pipe including the fittings

The minimum horizontal distance from a plumbing vent termination and a property line is

1.8m (6’)

The most downstream clean out on a building drain should be located

At or near the building wall

ABS-DWV solvent is:

Yellow

The minimum grade on a 3drainage pipe is

1/4 “ per foot (2%)

The minimum size of a roof ring serving of 3” vent is

4”

The clean out plug for cast-iron trap must be made of

Brass

The minimum rate of flow in a building sewer is

2 ft./sec

The minimum size of a building sewer servicing a public sewer is

4

The keyword for preventing drainage from backing up is

Backwater valve

The factors which would affect the size of a building drain are

Grade


Minimum size


And hydraulic load

The factors which would affect the size of a branch are

The hydraulic load

The factors which would affect the size of a branch are

The hydraulic load

The maximum distance between clean outs (two way rodding) on a 2” fixture drain is

15m (50’)

Are cleanouts required for soil or waste stacks?

Always

Soil pipe bends are ordered by?

Fractions of 360°

The minimum size clean out serving a 4 inch branch is

3”

A sanitary tee in a drainage system maybe used to change direction from

Horizontal to vertical

Fixture unit is a design factor for drainage systems one fixture unit is equal to

6.25 imp gallons drained into an 1 1/4” pipe over 1 minute.

Fixture unit is a design factor for drainage systems one fixture unit is equal to

6.25 imp gallons drained into an 1 1/4” pipe over 1 minute.

A Building sewer starts

1m outside of the building

A pipe positioned at 45° from the vertical is considered to be

Vertical

An individual vent can serve

One fixture ( vent is sized by a table based on fixture trap size)

What is the smallest trap allowed underground?

1 1/2”

When wet venting, what rules must apply?

Fixtures on the same story, fixtures connected separately or directly, water closet is the lowest trap arm

A fixture must be at least as large as

The fixture drain and the fixture outlet pipe

A Chase would most likely have

Pipe in it

A Chase would most likely have

Pipe in it

The maximum developed length of a continuous waste from a fixture waste opening to the water level in a trap is

1200mm

A vent terminal must

Be located 3.5 m away from an opening of a window or air inlet and be located at least 1 m above an opening window or air inlet

If fixture with 2trap is not listed in table 2.4.9.3, it’s hydraulic load will be determined as

3 Fixture units

Do usual fixture outlet pipe size for a bathtub is

1 1/2” (38mm)

The maximum length of a 4floor drain trap arm at min grade is

32 feet

The minimum size of an individual event serving a kitchen sink is?

1 1/4” (30mm)

The minimum length of a trap arm, 40mm in diameter, is?

80mm

What is the maximum cumulative change of direction the cleanouts are required on the fixture drains serving a commercial kitchen sink or trip receptacle?

90°

What would be the maximum number of tank type water closets that could drain into a 3” wet vent?

None

When wet venting over 4 stories how do you size your stack vent?

The same size as the wet vent

What is the largest size trap arm that can drain into a wet vent ?

3” emergency floor drain

What would be the maximum number of tank type WC’s that could drain into a wet vent?

0