Minimum boiler clearances vertically

18 in

Minimum boiler clearance for sides and rear

18 in

Minimum boiler clearances from the front

48 in

When can a generator installed for the production of carbon dioxide in a greenhouse take its combustion air from inside the greenhouse

When the rate of combustion does not exceed 20 BTU H per foot cubed the greenhouse volume and the concentration of CO2 does not exceed 5000 PPM and the concentration of Co does not exceed 35 PPM

What may be used to connect the dryer exhaust and a rigid moisture duct

A certified flexible foil non-combustible type duct

Dryer moisture exhaust duct termination distances

Not less than three feet from a pressure regulator vent terminal and not less than 10 feet from a fresh air intake

A moisture air duct shall not be secured with

Screws

Can you vent a moisture in exhaust duct into vent connector vent or chimney

No

High temperature limit control maximum setting for a gravity furnace

350° Fahrenheit or 175 degrees Celsius

High temperature limit control maximum setting on a forced air furnace

250° Fahrenheit or 120 degrees Celsius

Minimum clearance from the top of a central furnace

1 in

Minimum clearance from combustibles cereal for the jacket sides and rear of a central furnace

6 in

Minimum clearance distance from the front of a central furnace

24 in

Can you install a floor furnace

No

Where shall a direct fired make-up air heater not be used to supply makeup are

To an area where sleeping accommodation is provided

Max length of a gas hose used to connect a infrared tube heater

36 plus or minus 6 in

A room heater in a bathroom shall be of what type

Direct vent

When a room heater is installed in a room where sleeping accommodations provided or in a public area it shall

Be of the automatic temperature control type, be equipped with a pressure regulator, have 100% safety shut-off control, and be vented

Minimum distance of a pool heater to a property line

18 in

Can a pool heater be installed beneath any structure including a deck

No

Where should offended tube type pool heater be installed

Either Outdoors or in an enclosure that is not normally occupied and does not directly communicate with occupied areas

Minimum clearance from combustible material for any under fired storage type water heater shall be how many inches

2 in

Minimum clearance for any type of water heater other than an under fired storage type water heater shall be how many inches

6 in

When installed in a garage what is the minimum clearance that shall be maintained between the base of a heater and the garage floor

8 feet

Minimum clearance distance for a bracket or pendant gas light fixture from above

18 in

Minimum clearance for all sides of a bracket or pendant gas light fixture

5 in

Can you install a gas range in a bedroom

No but you may install one in a bed sitting room